• 5kVA-1000kVA Solar isolation transformers
5kVA-1000kVA Solar isolation transformers
discuss personally
Model
SG-200kVA
SG-100kVA
SG-1000kVA
Basic info
Brand ROCKWILL
Model NO. 5kVA-1000kVA Solar isolation transformers
Rated frequency 50/60Hz
Rated capacity 200kVA
Series SG
Product Detail

Product Overview

The transformer is the main component of various power supplies and electrical equipment, the transformer is composed of cylindrical windings and laminated iron cores, and the iron cores are stacked with new high-quality high-silicon silicon steel sheets and fully mitered joints. The company adopts advanced production technology, with imported Spanish winding machine and a full set of vacuum pressure impregnation equipment; The winding adopts the whole column winding method; Vacuum impregnation of the transformer to make the insulation grade of the transformer reach class F or H. The output and input voltages of the transformer can be designed according to customer needs.

Product features:

  • Scientific and reasonable design, the voltage change rate is controlled within 1~1.5%.

  • It is made of high-quality new silicon steel sheet, which can effectively reduce iron loss and improve efficiency.

  • It is made of high-quality wire rod with high temperature resistance, which minimizes its own loss and greatly improves the efficacy.

  • The use of H-class insulation, high temperature resistant insulation materials, improve the high voltage strength, insulation grade, and prolong the service life.

  • High efficiency design, up to more than 98%.

  • Patented design, beautiful, novel, high power density, small size, high space utilization.

  • The product chassis is divided into stainless steel and iron boxes, and there are inlet and outlet holes outside the box shell for the installation of power lines. If necessary, voltmeter, ammeter, temperature control alarm system, etc. can be added according to user requirements.

Technical data:

Product Advantages:

  • 100% full power.

  • Imported silicon steel sheet Low iron loss High magnetic induction strength.

  • LED display Clear and intuitive display.

  • Adopt high temperature resistant DM0.2 insulating paper Insulating sleeve 155°C.

  • Pure copper coil Wire two-layer insulating paint Low wire loss Not easy to oxidize.

  • The box has a built-in cooling fan,Intelligent control of temperature control meter .

  • The chassis is painted with the latest technology, and the rainproof design is IP65 certified.

Material description of transformer:

  • Iron core:Adopts new high-quality high-silicon silicon steel sheet, the main material is 0.35 thick H18, H14, H12, Z11 high-quality silicon steel sheet, we select the most suitable material according to customer requirements and use conditions, so that the transformer performance design to achieve the best. (The conventional material is a new high-quality silicon steel sheet).

  • The wire:Rod is made of PEW, UEW, EIW, SEIW, FEAI enameled wire and glass wire coated wire, and the temperature resistance level is F class (155 °C), H class (180 °C), HC class (200 °C), C class (220 °C). (The conventional temperature resistance level is H class 180°C).

  • Insulating material:High temperature resistant insulating paper is used as insulating material, which has multiple properties of high temperature insulation, flame retardant and moisture resistance.

  • Terminal block :The terminal block adopts the terminal block for small power, which is beautiful in appearance and has excellent voltage resistance, temperature resistance and flame retardant performance. The high power adopts high-quality copper bar.

  •  Iron feet:Mainly use CNC bending cold plate

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the